Volume 30, Issue 2 (Supplementary 2026)                   IBJ 2026, 30(2): 56-56 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Siami Z. Chronic Culture-Negative Infection Following Rhinoplasty with Repeated Cartilage Graft Failure: Successful Treatment with Dielectric Barrier Discharge Plasma Therapy–A Case Report. IBJ 2026; 30 (2) :56-56
URL: http://ibj.pasteur.ac.ir/article-1-5559-en.html
Abstract:  
Introduction: Post-rhinoplasty infection, though rare, can lead to severe complications, including tissue necrosis, nasal deformity, and failure of reconstructive grafts. Chronic culture-negative infections pose a particular diagnostic and therapeutic challenges, often associated with biofilm formation and poor response to conventional treatments.
Case Presentation: We report the case of a 49-year-old woman with no underlying comorbidities who developed a chronic, culture-negative infection following rhinoplasty. Over a three-year period, the patient experienced persistent purulent discharge, tissue necrosis, and repeated failures of reconstructive surgeries, including soft tissue reconstruction and costal cartilage grafting. Despite prolonged courses of antibiotics and several surgical interventions, her condition persisted, with microbiological cultures remaining negative. In 2025, she was referred to a specialized wound clinic, presenting signs of active infection, nasal tissue instability, and a markedly elevated C-reactive protein (CRP) level of 100 mg/L. Given the refractory nature of the infection, a combined treatment approach was initiated, consisting of broad-spectrum antibiotics (meropenem and linezolid) and dielectric barrier discharge (DBD) cold plasma therapy applied to both nostrils. Remarkably, complete cessation of nasal discharge was observed within one week of initiating plasma therapy. After one month, the CRP level decreased to below 10 mg/L, and clinical examination revealed complete resolution of infection, inflammation, and tissue necrosis, with stable wound healing.
Results and Discussion: After plasma therapy, the mean wound size decreased from 12.4 ± 8.7 to 6.8 ± 5.3 cm², and wound depth was reduced from 5.2 ± 3.1 to 2.7 ± 1.9 mm. The proportion of infected wounds declined from 33% to 11%, and pruritus decreased from 36% to 14%. Inflammatory markers (ESR and CRP) showed notable reductions, and patients reported fewer adverse symptoms after treatment. These findings indicate significant improvement in wound characteristics and treatment-related outcomes following plasma therapy.
Conclusion: This case highlights the potential role of DBD cold plasma therapy as an effective adjunctive treatment for chronic, resistant, and culture-negative infections following rhinoplasty. Cold plasma may offer a promising strategy for disrupting biofilms, reducing microbial burden, and controlling chronic inflammation in complex post-surgical wounds.

 
Type of Study: Congress | Subject: Related Fields

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2026 CC BY-NC 4.0 | Iranian Biomedical Journal

Designed & Developed by : Yektaweb