Volume 11, Issue 3 (7-2007)                   IBJ 2007, 11(3): 193-198 | Back to browse issues page

PMID: 18051780


XML Print


Abstract:  
Accurate measurements of physical characteristics of bone are essential for diagnosis, assessment of change following treatment, and therefore, indirectly, for evaluation of new forms of therapy. This is particularly true of osteoporosis and aging skeleton, in which fractures occur easily. Methods: In this study an ultrasonic system was set-up and calibrated on Plexiglas tubes of variable thickness then used to detect the cortical bone thickness change in calf and bovine adult femurs. Lamb waves have been generated and detected using a pair of Piezoelectric point transducers (transmitter and receiver) operating at 60 kHz in contact with the surface of the bone. Results: A link has been established between the ultrasound velocity and the bone thickness. On the other hand, the density variation has been also investigated by the simulation of the bone decalcification chemically. The results show that the velocity is very sensitive to both thickness and density, its value reduces as the cortical bone thickness and density decrease. Conclusion: This technique might be considered in the attendance of certain bone diseases expressing itself by gradual change in physical properties.
Type of Study: Full Length/Original Article | Subject: Related Fields

Rights and permissions